This document describes the HydrOffice Sound Speed Library and Manager (2026.3). For the source code, go here.
4. SSM-SIS app¶
The SSM-SIS app is a simple application used to check the settings/interaction between Sound Speed Manager and Kongsberg SIS (Fig. 4.1).
Warning
To avoid interference with Sound Speed Manager keep it closed while using SSM-SIS.
Fig. 4.1 The SSM-SIS app with the default parameters.¶
4.1. Settings¶
Note
For the settings required on the SIS side, see SIS v5 settings using Sound Speed Manager (SSM) IP and port field and SIS v5 settings through Data Distribution (legacy method).
The Settings group box lists the app configuration settings:
SIS Version: switching between SIS4 and SIS5 loads the default settings for each of the two options.
Input port: the port used by SIS to broadcast the datagrams.
Output IP: the IP address of the SIS machine.
Output port: the port used by SIS to receive the sound speed profile. The default port should work.
Verbose: this flag increases the number of debug messages printed in the windows shell by the SSM-SIS app.
4.2. Commands¶
The Commands group box lists the app commands:
Start: to start the listening of SIS datagrams.
Require SSP: to send a message to SIS that should trigger the reception of the sound speed profile currently in use by Kongsberg SIS.
Send SSP: to send a fake sound speed profile to Kongsberg SIS. It should also trigger the reception of the same speed profile.
Stop: to end the listening of SIS datagrams.
Warning
Do not use the Send SSP command during regular survey operations because it will trigger the transmission of a fake sound speed profile.
4.3. Output¶
The Output view provides updates on the received and transmitted datagrams (Fig. 4.2).
Fig. 4.2 The SSM-SIS app showing the results of the interaction with Kongsberg SIS5.¶